PD digital controller is compact and easy to install. PD digital controller has high accuracy of output voltage, which can be controlled by button or RS232 to achieve brightness adjustment of 0-255 levels. It can be used as ordinary illuminator controller, and trigger control can be realized (trigger can be realized by RS232 or external trigger).
1.Easy to operate, each channel can be controlled independently with high precision.
2.Digital display, button control, easy to understand.
3.Can communicate with PC by RS232.
4.With trigger, faster respond speed, high reliability.
5.Power off saving function.
Parameters
Item | LTS-PD2460-4 | LTS-PD24120-8 | Remark |
Number of channels | 4 way | 8 way | |
Addition output voltage | 12V/500mA | N/A | Power supply to camera or other device. This interface strictly prohibit reverse connected |
Input voltage | AC 100-240V | ||
Input frequency range | 50/60Hz | ||
Output voltage range | 0-24V | ||
Luminance control method | Manual adjust by button, PC remote adjustion | ||
Luminance control mode | PWM adjust | Change PWM duty radio to adjust voltage | |
Luminance control Level | 256 level | ||
Saving function | Self-saving parameter of luminance when power off | ||
External trigger voltage | 5-24V | ||
Communication method | RS232 serial port communication | ||
Normal on/Normal closed mode switch | Change H mode by CH button | H1 mode is normal on H0 mode is normal closed |
Control panel specification < LTS-PD2460-4 >
Connection step:
Step 1: connected the light and controller (Reference to the picture on the right).
Step 2: if need the external trigger control, please connect the external trigger signal with the controller trigger interface.
Step 3: connect power (AC100-240V 50/60 Hz), press the red switch “-”, indicator light up, “o” uplifted, power on.
Step 4: If need to control the luminance by PC, please connect the PC with controller by RS232 data line in the power off status, then control by our demo program or the program you write yourself. Can set-up the each channel parameter manual when operated by serial port mode. That’s to say, the upper computer and controller all can set-up the parameter, no need mode swapping.
Trigger port setup < LTS-PD2460-4 >
This series controller is high level trigger. Total 4 group trigger ports, each has +,- mark. To input high level to +,- port can achieve the trigger function.
Specification: T1 is trigger delay time,T1≤200us,T3≤200us。
Coding rule
Product | Model | Output voltagerange | Total output power | One way Max.output power | Number ofchannels | Extenal triggervoltage | Remark |
---|---|---|---|---|---|---|---|
Digital controller | LTS-PD2460-4 | 0-24V | 60W | 40W | 4 | 5-24V | Have voltage display, trigger, and power supplyto camera function |
LTS-PD24120-8 | 0-24V | 120W | 60W | 8 |